,Cathode Ray Tubes,Ceramic Tubes,CFA,chemical synthesis,chromenes,CO2 sensors,Communication,composite membranes,condensed heterocycles,Control Tubes,CWT,database,Devices,Diodes,Discharger,Display Tubes,Electron Tubes,Electron,antitumor,artificial organs,artificial skin,Attenuators,Audio tubes,Backward Wave Oscillator,Band filtering,Beam tubes,biocompatibility,biomaterials,biosensors,Broadcast,Broadcasting Tubes,Broadcasting,carbon dioxide isolation3CX300A1,4CX400A,4CX800A,4X150A,6360,6BK4,6BQ7.6C19,6C33C,6D22S,6N1P,6S19P,7034,813,829A,832A,833A,absorbent,Acquisition,Aircraft,Amateur Radio,Amateur,Amplifiers,Antenna amplifiers,anticancer compounds,antitumor agent,Modular Pulse Tubes,Modular,Pulse,Russia,component,Navigator,product,characteristics,tube,technical,information,diagram">
GMI-83V
TETRODE
The GMI-83V tetrode is used as a power amplifier in pulse modulator circuits
GENERAL
Cathode: indirectly heated, oxide-coated.
Envelope: glass, with base.
Height: at most 146.5 mm.
Diameter: at most 65 mm.
Mass: at most 300 g
00011.jpg)
1 - grid 1; 2 - cathode and heater; 3 - heater; 4 - grid 2; A - anode-top cap
| OPERATING ENVIRONMENTAL CONDITIONS | |
| Ambient temperature, °C | -10 to +55 |
| Relative humidity at up to 25 °C, % | 98 |
|
BASIC DATA Electrical Parameters |
|
| Heater voltage, V | 25 |
| Heater current, A | 2-2.5 |
| Peak anode current, A, at least | 15 |
| Peak grid 2 current and peak grid 1 current (at anode voltage 20 kV, grid 2 voltages 1.25 kV, grid 1 voltage -800V, peak grid 1 excess voltage 250 V), A, at least | 0 |
| Cutoff voltage, V | 300-700 |
| Interelectrode capacitance, pF: | |
| input | 30-35 |
| output | 5-11 |
| transfer, at most | 1 |
| Electric strength (at anode voltage 20 kV, grid 2 voltage 1.25 kV, grid 1 voltage -800 V, peak grid 1 excess voltage 250 V, pulse duration 2 µs, pulse frequency 500 pulses/s), number of sparkings, at most | 25 |
| Electrical parameters over 500 h of service: | |
| peak anode current, A, at least | 13 |
| electric strength, number of sparkings: | |
| for 80 % of tubes, at most | 20 |
| for 20 % of tubes, at most | 50 |
| Limit Operating Values | |
| Heater voltage, V | 22.5-27.5 |
| Anode voltage, kV | 18 |
| Grid 1 voltage, kV | -1 |
| Grid 2 voltage, kV | 1.25 |
| Peak grid 1 excess voltage, V | 250 |
| Peak cathode current, A | 25 |
| Dissipation, W: | |
| anode | 60 |
| grid 2 | 9 |
| grid 1 | 3 |
| Pulse duration, µs | 5 |
| Warm up time, s, at least | 180 |
| Temperature at envelope and seals, °C | 200 |
00021.jpg)
Averaged Peak Anode-Grid Characteristic Curves:
Uf = 25V; Ug2 = 1kV; Ug1 = -800V; Ug1 imp = 250V;
_____ anode;
_ _ _ grid-anode
00022.jpg)
Averaged Peak Anode-Grid Characteristic Curves:
Uf = 25V; Ug2 = 1.25kV; Ug1 = -800V; Ug1 imp = 250V;
_____ anode;
_ _ _ grid-anode
00031.jpg)
Averaged Peak Anode-Grid Characteristic Curves:
Uf = 25V; Ug2 = 1.25kV; Ug1 = -800V
00032.jpg)
Characteristic Curves of Grid 1 Cutoff Voltage versus Anode Voltage